Home Company Products News Downloads Contact
Quick link
Product focus
How to secure a guard door (closed AND locked)
and
prevent access to
a dangerous area at
the same time?


Discover Vigilguard and Anaguard!



Quality management



Relays
  • DLC Electonic Current Limiting Circuit Breakers provide automatic reset with a fast response of 20mS, assuring that they meet requirements of Safety Category 4,
  • Some relays feature selectable Manual or Automatic Reset Function set with a dip switch on the back, to prevent access after installation,
  • Relays are designed to be used with BTI non-contact switches as well as standard mechanical switches such as keyed safety interlocks and e-stops.


AWAX 26 XXL


SAFETY RELAY
  • power supply 24 V AC/DC
  • manages up to 30 non stand-alone switches or mechanical switches with 2NO safety lines
  • selectable reset: auto/manual adjustable on the back thanks to DIP Switch
  • 8A/250Vac or 8A/250Vdc
  • 3 safety lines NO + 1 aux line NC
  • Category 3 or 4
  • Dual channel operation, with short circuit/link monitoring of e-stop input.
  • 3 LEDs status display

AWAX 25 XL


SAFETY RELAY
  • power supply 24 VDC
  • manages up to 30 non stand-alone switches or mechanical switches with 2NO safety lines
  • 8A/250Vac or 8A/250Vdc
  • 2 safety lines NO + 1 aux line NC
  • Category 3 or 4
  • Dual channel operation, with short circuit/link monitoring of e-stop input.
  • Internal auxiliary power supply protection with automatic reset: DLC system
  • 1 LED status display

AWAX 27 XXL

SAFETY RELAY (2 ZONES MONITORING)
  • manages up to 30 non stand-alone switches or mechanical switches with 2NO safety lines
  • copper plug-in terminal
  • DLC system
  • selectable reset: auto/manual adjustable on the back thanks to DIP Switch
  • 8A/250Vac or 8A/250Vdc
  • 6 safety lines NO + 2 aux line NC

CO13XXL

EMERGENCY STOP CONTROL
  • auto-adaptative to single or dual channel inputs
  • selectable restarting: auto/manual (adjustable on the back thanks to DIP Switch)
  • single channel : cat.2
  • dual Channel: cat.3
  • 8A/250Vac or 8A/250Vdc
  • 3 LEDs status display

CO13L

EMERGENCY STOP CONTROL
  • auto-adaptative to single or dual channel inputs
  • single channel : cat.2
  • dual Channel: cat.3
  • 8A/250Vac or 8A/250Vdc
  • 1 LED status display

COM 3C


TWO HAND CONTROL / SAFETY RELAY

  • Control of 2 buttons 1NO+1NC
  • Desynchronism between buttons : 0,4 sec.
  • 2NO + 1NC output contacts
  • Test input (position switches, contactors)
  • DLC short-circuit monitoring
  • Plug-in terminals
  • 3 LEDs status display
  • Cat IIIC acc. to EN 574

VALTRONIC
MONITORED RESTARTING MODULE
  • validates the restarting of a machine thanks to 2 reset buttons
  • Protection of an operator placed in a death zone
  • 2 independent lines of command to activate up
    to 2 safety systems & 1 NC auxiliary line
  • Pushing on 2 buttons of which 1 is priority
  • Delaying time adjustable by incremental coders
  • Delaying time: 0, 2, 4, 6, 8, 12, 16, 18, 20, 22s

SPEEDTRONIC


STANDSTILL DETECTOR
  • level of 0,02V to 0,7V left
  • timing from 2 to 7 scdes to open interlocks
  • 3 contacts NO + 1 contact NC 8A/250V
  • Selectable manual or automatic reset
  • Control of starting circuit
  • Compatible with frequency variator
  • Power supply : 24Vac/dc
EXELTRONIC XXL

  • Safety module with both delayed and instantaneous lines
  • Delaying time programmable from 0 to 999s
  • Activation by a dual channel pushbutton with 2contacts NC
  • Short-circuit monitoring of input
  • Compatible with safety switches fitted with Acotom process
  • 3NO instantaneous contacts for engine control 
  • or heating resistances of single- or three-phase motors
  • 2NO+1NC delayed contacts
  • Delay time adjustable by incremental coders (from 0 to 999s)
TIMTRONIC XXL
TIMING MODULE

  • For delayed interlockings opening (0 to 999 scdes)
  • Activation by an opening of a NO contact
  • Reset to zero each time the contact closes (LED lit off)
  • Flashing LED during timing
  • Closing of contacts after timing
  • Delay time adjustable by incremental coders from 0 to 999s
  • 2 NO delayed lines 8A/250V
  • 1 NC delayed line 8A/250V
C4TN
SAFETY TIMING MODULE

  • Timing module for machine
energization/un-energization
  • Delay from 1 to 22scdes
C4CK
CAPTIVE KEY MODULE

The key position takes over the switch status
  • Version A
  • Key locked and turned : 4NO+1NC 8A/250V
  • Key removed : 4NC+1NO 8A/250V
    Version B
  • Key locked and turned : 4NC+1NO 8A/250V
  • Key removed : 4NO+1NC 8A/250V
    Versions A and B
1 line for cyclical test and 2 LEDs
Relays list



COMITRONIC - ZI Nord des richardets - 34, Allée du closeau - 93160 NOISY LE GRAND - France Tel: +33 (0)143 030 303 - Fax: +33 (0)143 046 222
www.comitronic.net - export@comitronic.net

Copyright © 2006 - Comitronic - Design by Kits Graphiques TeKa
This website can not be copied, in integrality or partially, unless with the agreement of Comitronic. 2009, All rights reserved.